1.
J Vis Exp ; (193)2023 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-37067273

RESUMO

An experimental apparatus and a standard operating procedure (SOP) are developed to collect time-resolved data on the gas compositions and fire characteristics during and post-thermal runaway of lithium-ion battery (LIB) cells. A 18650 cylindrical cell is conditioned to a desired state-of-charge (SOC; 30%, 50%, 75%, and 100%) before each experiment. The conditioned cell is forced into a thermal runaway by an electrical heating tape at a constant heating rate (10 °C/min) in an environmental chamber (volume: ~600 L). The chamber is connected to a Fourier transform infrared (FTIR) gas analyzer for real-time concentration measurements. Two camcorders are used to record major events, such as cell venting, thermal runaway, and the subsequent burning process. The conditions of the cell, such as surface temperature, mass loss, and voltage, are also recorded. With the data obtained, cell pseudo-properties, venting gas compositions, and venting mass rate can be deduced as functions of cell temperature and cell SOC. While the test procedure is developed for a single cylindrical cell, it can be readily extended to test different cell formats and study fire propagation between multiple cells. The collected experimental data can also be used for the development of numerical models for LIB fires.


Assuntos
Incêndios , Lítio , Temperatura , Íons , Fontes de Energia Elétrica
SELEÇÃO DE REFERÊNCIAS